Monday, June 16, 2014

Transformer parametrisizing

since i had to rate a lot of 'em - i changed my prev. MMXIV-01-14 method - to a faster but not necessarily a better 1 the measurement schematic stays the same only the computations and what's being sampled a bit varies -- an example::

12VAC ~AC-TEST 12VAC DC-TEST (Full-Cycle Rectified)
IL1(mA) UL1(V) ZL1(Ω) UL2(V) UL1:UL2 LABEL VALUE(Ω) UIN(V) EBRIDGE(V) rBRIDGE(Ω) UIN.std.Z
16 234.2 14637.5 15.08 15.5305 1K5 1597.75 20.45 20.8 27.34535 20.55842
16.2 234.4 14469.14 15.09 15.53347 K91 893.625 20.2 20.8 26.54332 20.46157
16.5 235.2 14254.55 15.14 15.53501 K75 770.875 20.15 20.8 24.86694 20.42681
17 236.5 13911.76 15.22 15.53876 K51 515 19.75 20.7 24.77215 20.30202
17.6 237.7 13505.68 15.3 15.53595 K47 467.25 19.75 20.7 22.47532 20.26391
17.9 238.3 13312.85 15.33 15.54468 K39 395.25 19.44 20.6 23.58488 20.18945
18 238.5 13250 15.34 15.54759 K33D 323.5 19.26 20.58 22.17134 20.08323
18 238.5 13250 15.33 15.55773 K24 239.575 19.1 20.7 20.06911 19.88138
18 238.6 13255.56 15.34 15.55411 K20 205.97 18.82 20.51 18.49571 19.7565
18.1 238.8 13193.37 15.35 15.557 K10 101.125 17.92 20.6 15.1236 18.87996
18.6 239.9 12897.85 15.42 15.55772 K10G 95.95 17.87 20.6 14.65828 18.79162
18.8 240.2 12776.6 15.44 15.55699 51EA 50.75 16.66 20.67 12.21534 17.3766
19.5 241.5 12384.62 15.52 15.56057 26R 26.125 15.075 20.75 9.834784 15.1013
20.75 20.75
AVG :: 237.8692 13469.19 15.3 15.5364 Geom.Mean :: 20.68266 9.655674
Characteristic String : 21dW154dV138mA
Transformer Name : 12VAC
Label Value UL2(V) UL1(V) IL2(mA) IL2.Chk(mA)
1K5 1597.75 15.71 245.2 9.832577 9.871807 L1 Hz 50 1
K91 893.625 15.72 245.8 17.59127 17.66619 IL1(mA) 17.81844 0.867283
K75 770.875 15.62 244.1 20.26269 20.32819 VL1(V) 240 4.276427
K51 515 15.52 242.8 30.13592 30.16871 Z 13469.19 11.30787
K47 467.25 15.67 245.6 33.53665 33.59338 XL 13466.43 29.87655
K39 395.25 15.55 243.6 39.34219 39.27984 L(H) 42.86497 95.1mH
K33D 323.5 15.68 246.2 48.46986 48.27218 R1(Ω) 272.75 0.177579
K24 239.575 15.73 247.8 65.65794 64.83922 L2 R2(Ω) 1.2 29.90064
K20 205.97 15.57 245.4 75.59353 74.0185 L(mH) 177.5786 55.80086
K10 101.125 15.28 243.3 151.1001 135.5857 VL2(V) 15.4476
K10G 95.95 15.17 241.7 158.1032 140.1582
51EA 50.75 14.75 239.8 290.6404 204.6301
26R 26.125 14.28 241.7 546.6029 252.4927

in short :: the ~AC-TEST -- returns ZL1(Ω) and Voltage transfer ratio - which are used in computing the LL2(mH) , UL2(V) AND IL2.Chk(mA) , e.c. ...

the dynamic ~AC-TEST (under the  [ Transformer Name : ] ) -- returns from UL1(V) , UL2(V) , RTEST.N(Ω) -- /!\ /!\ something IL2(mA) which are then checked against the ~AC-TEST based computed IL2.Chk(mA)

from this it seems that the TF(transformer)'s  power transfer is dependent on it's load -- see the RBRIDGE(Ω) under the DC-TEST -- //// -- so you need to adjust the LL2(mH) to match your circuit's average op.-g conditions (the previous method matched the average test range)

note::the "Characteristic String"  is described in HERE for more detail -- it's more meaningful inside the set of such for multiple TF-s -- has a comparative purpose.

[EOF]

MMXIV-09-08 note :: i in principle won't remove the below Bsh - the Blogger editor is (still - i guess) unpredictable (the 1-st impresion tends to stay - even more if there's no tendency to improvement throughout several . . . years ◄ such fixes a permanent attitude like below - i suggest you don't focus)

sub-note: Kuradi sita virvendus! Mõlemad - Blogger ja FF - nii koos kui eraldi -- üks kukub ära ja teine ei saa hakkama -- eriline utoopia on mingit asja siin üldse aretada kui debiilikud on töövahendeid üritanud teha (hea on kui see asi nüüd nii jääb nagu ta praegu paistab (kuradi idiootide maa - nahhui . . . persse!)) - no offence this is how i see it . . . i always wondered why people remove their blogs - i guess such may be a reason - if you try to do it (blog) too often - it eats the last of your nerves off . . .